YJJ 8410179 Original Flow Sensor Of Delger Is Used In Intensive Care Unit In Operating Room

Certificado
CHINA ShenzhenYijiajie Electronic Co., Ltd. Certificações
CHINA ShenzhenYijiajie Electronic Co., Ltd. Certificações
Estou Chat Online Agora

YJJ 8410179 Original Flow Sensor Of Delger Is Used In Intensive Care Unit In Operating Room

YJJ 8410179 Original Flow Sensor Of Delger Is Used In Intensive Care Unit In Operating Room
YJJ 8410179 Original Flow Sensor Of Delger Is Used In Intensive Care Unit In Operating Room YJJ 8410179 Original Flow Sensor Of Delger Is Used In Intensive Care Unit In Operating Room YJJ 8410179 Original Flow Sensor Of Delger Is Used In Intensive Care Unit In Operating Room YJJ 8410179 Original Flow Sensor Of Delger Is Used In Intensive Care Unit In Operating Room

Imagem Grande :  YJJ 8410179 Original Flow Sensor Of Delger Is Used In Intensive Care Unit In Operating Room

Detalhes do produto:
Place of Origin: USA
Marca: YJJ
Model Number: 8410179
Condições de Pagamento e Envio:
Minimum Order Quantity: 1
Preço: Negociável
Packaging Details: Box pack
Delivery Time: 5 to 8 working days
Payment Terms: L/C, D/A, D/P, T/T, Western Union, MoneyGram
Supply Ability: 1500

YJJ 8410179 Original Flow Sensor Of Delger Is Used In Intensive Care Unit In Operating Room

descrição
fluxo de suporte: 0 - 348 PA Etapas de limpeza‌: Habitação
Fonte de energia: 24 VAC/VDC, Power Sinal de saída: 0 - 2,5 VCC
Tamanho: Aproximadamente 8,6 cm Largura: 3,8 cm
Destacar:

Delger ICU flow sensor

,

medical air flow sensor for operating room

,

YJJ 8410179 original flow sensor

Product Description:

YJJ 8410179 Original Flow Sensor of Delger Is Used in Intensive Care Unit in Operating Room

 

Features:

8410179 Flow Sensor is a dedicated neonatal flow sensor for Drager ventilators. It measures gas flow using the hot wire velocity measurement method and is mainly used in compatible devices such as Evita Infinity V500. The following is the description of its key parameters:
Measurement principle
It adopts the hot wire velocity measurement method. By measuring the cooling effect of gas flow on the hot wire, the flow velocity can be calculated. This method is suitable for precise monitoring of gas flow rates such as air and oxygen.
Scope of Application
‌Device Compatibility‌: Only applicable to specific models of ventilators (such as Evita Infinity V500). Please refer to the device manual for confirmation of compatibility.
Applicable scenarios: Newborn respiratory support. The measurement range of support flow is 0 - 348 Pa (approximately 0 - 1.4" wc).
Maintenance and Disinfection
‌Cleaning Steps‌: The housing and the measuring instrument's plug need to be soaked in a dedicated cleaning solution, and the Y-shaped connector and the internal part of the measuring instrument should be cleaned with a lint-free brush.
Disinfection method: When using immersion disinfection, make sure the solution completely covers all surfaces. After disinfection, thoroughly rinse off any remaining solution.
Performance parameters
Power supply: 24 VAC/VDC, power consumption approximately 0.5 VA.
Output signal: 0 - 2.5 VDC, requires an external converter for processing.
Size: Approximately 8.6 cm in length × 3.5 cm in width × 3.8 cm in height (including the casing).
Environmental Requirements: Working temperature -10℃ to 60℃, transportation temperature -40℃ to 80℃, relative humidity 10% to 85%.
This sensor needs to be inspected regularly for any damage, stains or particles on its surface. If the measurement line continues to emit light, it must be replaced immediately.

 

Spirolog Universal flow sensor (5 / box)

 

Infinity ID wireless Transmission flow sensor (5 PCS/box)

 

MK01900 SpiroLife long-acting universal flow sensor

 

8410185 Y-type flow sensor adapter

 

ISO type flow sensor adapter 8411130

 

Pressure differential flow sensors for 8412034 Oxylog and Fabius2000

 

8410179 Inserted hot wire sensors (5 / box) for 8410185 and 8411130

 

Specifications:

General packaging Single-tube type
RoHS Compliance
Installation method Through-hole installation
Working temperature -40℃ to 125℃

 

YJJ 8410179 Original Flow Sensor Of Delger Is Used In Intensive Care Unit In Operating Room 0